Australian PFC Channels: Dimensions & Section Properties
Dimensions and section properties of parallel flange channels (PFC) to AS/NZS 3679.1
Parallel flange channels (PFC)
| Section | Geometry | Bending | Axis y–y | Bending | Axis z–z | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| h | b | tw | tf | r₁ | Cy | Cz | A | P | Mass | Iᵧ ⨯10⁶ | Wᵧ ⨯10³ | Wpl,ᵧ ⨯10³ | iᵧ | Sᵧ ⨯10³ | Iz ⨯10⁶ | Wz (L) ⨯10³ | Wz (R) ⨯10³ | Wpl,z ⨯10³ | epl,z | iz | Sz ⨯10³ | |
| [mm] | [mm] | [mm] | [mm] | [mm] | [mm] | [mm] | [mm²] | [mm] | [kg/m] | [mm⁴] | [mm³] | [mm³] | [mm] | [mm³] | [mm⁴] | [mm³] | [mm³] | [mm³] | [mm] | [mm] | [mm³] | |
| 75 PFC | 75.00 | 40.00 | 3.80 | 6.10 | 8.00 | 13.75 | 37.50 | 754 | 296 | 5.92 | 0.683 | 18.22 | 21.38 | 30.10 | 10.69 | 0.120 | 8.72 | 4.56 | 8.15 | -4.59 | 12.60 | 4.20 |
| 100 PFC | 100.00 | 50.00 | 4.20 | 6.70 | 8.00 | 16.66 | 50.00 | 1 061 | 385 | 8.33 | 1.74 | 34.71 | 40.28 | 40.44 | 20.14 | 0.267 | 16.03 | 8.01 | 14.37 | -6.24 | 15.86 | 7.45 |
| 125 PFC | 125.00 | 65.00 | 4.70 | 7.50 | 8.00 | 21.77 | 62.50 | 1 520 | 494 | 11.93 | 3.97 | 63.51 | 72.97 | 51.11 | 36.48 | 0.658 | 30.22 | 15.22 | 27.21 | -7.42 | 20.81 | 14.02 |
| 150 PFC | 150.00 | 75.00 | 6.00 | 9.50 | 10.00 | 24.91 | 75.00 | 2 254 | 579 | 17.70 | 8.34 | 111.20 | 128.58 | 60.83 | 64.29 | 1.29 | 51.61 | 25.67 | 46.05 | -9.23 | 23.88 | 23.84 |
| 180 PFC | 180.00 | 75.00 | 6.00 | 11.00 | 12.00 | 24.53 | 90.00 | 2 660 | 638 | 20.88 | 14.13 | 157.03 | 181.62 | 72.89 | 90.81 | 1.51 | 61.52 | 29.90 | 53.84 | -9.94 | 23.82 | 28.02 |
| 200 PFC | 200.00 | 75.00 | 6.00 | 12.00 | 12.00 | 24.40 | 100.00 | 2 918 | 678 | 22.91 | 19.11 | 191.05 | 220.97 | 80.91 | 110.48 | 1.66 | 67.83 | 32.71 | 58.95 | -10.13 | 23.82 | 30.72 |
| 230 PFC | 230.00 | 75.00 | 6.50 | 12.00 | 12.00 | 22.62 | 115.00 | 3 201 | 737 | 25.13 | 26.77 | 232.77 | 271.39 | 91.44 | 135.70 | 1.76 | 77.83 | 33.62 | 61.05 | -13.31 | 23.45 | 32.92 |
| 250 PFC | 250.00 | 90.00 | 8.00 | 15.00 | 12.00 | 28.57 | 125.00 | 4 522 | 834 | 35.50 | 45.14 | 361.14 | 420.72 | 99.91 | 210.36 | 3.64 | 127.52 | 59.31 | 107.39 | -13.80 | 28.38 | 56.60 |
| 300 PFC | 300.00 | 90.00 | 8.00 | 16.00 | 14.00 | 27.23 | 150.00 | 5 109 | 932 | 40.10 | 72.42 | 482.77 | 563.68 | 119.06 | 281.84 | 4.04 | 148.51 | 64.43 | 116.98 | -16.01 | 28.14 | 63.04 |
| 380 PFC | 380.00 | 100.00 | 10.00 | 17.50 | 14.00 | 27.49 | 190.00 | 7 035 | 1 128 | 55.22 | 151.72 | 798.51 | 946.27 | 146.86 | 473.13 | 6.48 | 235.82 | 89.39 | 160.81 | -18.23 | 30.36 | 92.02 |
Note: S here is the first moment of area, not the plastic section modulus. Elastic and plastic section moduli are W and Wpl (Z and S in AS 4100). Axes y–y and z–z correspond to x–x and y–y in AS 4100.
Values are calculated with the Section Properties Calculator. They usually differ from published catalog values by about 0.5%, and by up to 1% in rare cases, mostly for small sections. See how the values are calculated.
About Australian PFC channels
Parallel flange channels (PFC) are hot-rolled channels made to AS/NZS 3679.1 and designed to AS 4100. The designation gives the nominal depth in millimetres — 150PFC is a channel about 150 mm deep. As the name says, the flanges have parallel inner faces, like the European UPE and unlike the tapered-flange UPN or American C-shapes. Parallel flanges make bolted and welded connections simpler, since no tapered washers are needed.
A channel is not symmetric about its web, so its shear centre lies outside the section, on the outer side of the web, away from the flanges. A load applied through the web therefore tends to twist a single channel. This is why PFCs are used where the load acts close to the shear centre or the member is restrained against twisting: edge and trimmer beams, lintels, stair stringers, frames around openings and bracing. The flat back of the web is convenient for fixing against a wall or another member.
Two channels placed back to back or toe to toe form a symmetric section without this twisting effect, which is a common choice for columns, truss chords and struts.
Notations
Symbols used in the Australian PFC table. Units are shown in the table headings.
Geometry and mass
- Section
- Profile designation in the AS/NZS 3679.1 catalogue.
- h
- Overall section depth.
- b
- Flange width.
- tw
- Web thickness.
- tf
- Flange thickness.
- r1
- Root radius at the web-to-flange junction.
- Cy, Cz
- Centroid coordinates measured from the lower-left reference corner.
- A
- Cross-sectional area.
- P
- Perimeter of the section's outer contour.
- Mass
- Calculated mass per metre using a steel density of 7,850 kg/m³.
Bending properties
- Iy, Iz
- Second moments of area about the centroidal y–y and z–z axes.
- Wy,max, Wy,min; Wz,max, Wz,min
- Elastic section moduli about the y–y and z–z axes at the nearer and farther extreme fibres.
- iy, iz
- Radii of gyration about the y–y and z–z axes: i = √(I/A).
- Sy, Sz
- First moments of one half of the section area about the centroidal axes.
Plastic properties
- Wpl,y, Wpl,z
- Plastic section moduli about the plastic neutral axes for bending about y–y and z–z.
- epl,y, epl,z
- Offsets of the plastic neutral axes from the corresponding centroidal axes.
In the mm view, table headings scale fourth-power properties by 10⁶ and cubic properties by 10³. The displayed multiplier applies to the values in that column.