UPN channels

SectionGeometry and MassIₚAxis y–yAxis z–z
hbtwtfb₁ir₁r₂CyAPMassIₚ ⨯10⁶Iᵧ ⨯10⁶Wᵧ ⨯10³Wpl,ᵧ ⨯10³iᵧSᵧ ⨯10³Iz ⨯10⁶Wz,max ⨯10³Wz,min ⨯10³Wpl,z ⨯10³epl,zizSz ⨯10³
[mm][mm][mm][mm][mm][mm][mm][mm][mm²][mm][kg/m][mm⁴][mm⁴][mm³][mm³][mm][mm³][mm⁴][mm³][mm³][mm³][mm][mm][mm³]
UPN 5050.0038.005.007.0019.000.087.003.5013.697122295.590.3560.26510.6012.9819.296.490.09106.653.746.89-3.0811.303.52
UPN 6565.0042.005.507.5021.000.087.504.0014.249032737.090.7150.57517.7021.4125.2410.710.1409.825.039.48-4.3712.444.90
UPN 8080.0045.006.008.0022.500.088.004.0014.521 1023138.651.251.0626.4831.9031.0015.950.19413.336.3512.08-5.6613.256.35
UPN 100100.0050.006.008.5025.000.088.504.5015.501 34537210.562.352.0541.0748.9739.0724.480.29118.808.4516.21-6.8314.728.59
UPN 120120.0055.007.009.0027.500.089.004.5016.061 69942913.344.073.6460.7372.7146.3136.350.43126.8111.0621.27-8.7915.9211.61
UPN 140140.0060.007.0010.0030.000.0810.005.0017.552 03748715.996.676.0586.41102.7854.4951.390.62535.5914.7228.32-9.4917.5115.36
UPN 160160.0065.007.5010.5032.500.0810.505.5018.392 40254518.8510.109.25115.60137.5562.0568.770.85046.2318.2535.16-10.8818.8219.37
UPN 180180.0070.008.0011.0035.000.0811.005.5019.282 79760321.9514.6713.54150.45179.1369.5889.561.1358.8522.3843.07-11.5120.1424.03
UPN 200200.0075.008.5011.5037.500.0811.506.0020.143 21966025.2720.5919.11191.10227.7777.05113.881.4873.3426.9351.89-12.1021.4229.29
UPN 220220.0080.009.0012.5040.000.0812.506.5021.453 74571829.4028.8726.91244.67291.5184.78145.751.9691.3333.4564.37-12.9422.8736.37
UPN 240240.0085.009.5013.0042.500.0813.006.5022.364 23177633.2138.4635.99299.92357.6992.23178.852.47110.6539.5075.96-13.5524.1843.30
UPN 260260.0090.0010.0014.0045.000.0814.007.0023.684 82983337.9051.4248.25371.12442.4499.96221.223.17133.9947.8391.90-14.3925.6352.39
UPN 280280.0095.0010.0015.0047.500.0815.007.5025.325 34289141.9466.7562.76448.31532.00108.39266.003.98157.2257.14109.80-15.7827.3062.02
UPN 300300.00100.0010.0016.0050.000.0816.008.0027.005 87794946.1385.2180.28535.22632.41116.88316.214.93182.6167.55129.90-17.2128.9772.68
UPN 320320.00100.0014.0017.5041.250.0517.509.0026.027 59298359.59114.95108.97681.04827.20119.81413.605.98229.8780.84152.49-14.1628.0789.00
UPN 350350.00100.0014.0016.0042.000.0516.008.0024.007 7341 04560.71134.40128.67735.28900.67128.98450.335.72238.4575.31142.92-12.9527.2085.77
UPN 380380.00102.0013.5016.0043.000.0516.008.0023.898 0471 11463.17164.07157.90831.041 016.75140.08508.376.17258.3279.00149.63-13.3027.6990.57
UPN 400400.00110.0014.0018.0046.000.0518.009.0026.859 1681 18271.97212.73204.181 020.901 239.50149.23619.758.55318.42102.80193.60-15.3930.53115.62

UPE channels

SectionGeometry and MassIₚAxis y–yAxis z–z
hbtwtfr₁CyAPMassIₚ ⨯10⁶Iᵧ ⨯10⁶Wᵧ ⨯10³Wpl,ᵧ ⨯10³iᵧSᵧ ⨯10³Iz ⨯10⁶Wz,max ⨯10³Wz,min ⨯10³Wpl,z ⨯10³epl,zizSz ⨯10³
[mm][mm][mm][mm][mm][mm][mm²][mm][kg/m][mm⁴][mm⁴][mm³][mm³][mm][mm³][mm⁴][mm³][mm³][mm³][mm][mm][mm³]
UPE 8080.0050.004.007.0010.0018.171 0073437.911.331.0726.8131.2332.6315.620.25413.997.9813.95-4.1415.897.09
UPE 100100.0055.004.507.5010.0019.061 2514029.822.452.0741.3848.0240.6724.010.38220.0510.6318.88-5.7517.489.69
UPE 120120.0060.005.008.0012.0019.831 54246012.114.193.6460.6070.3548.5635.170.55427.9413.7924.80-7.8018.9512.91
UPE 140140.0065.005.009.0012.0021.731 84252014.466.786.0085.6598.8757.0549.430.78736.2218.1932.58-7.8520.6716.85
UPE 160160.0070.005.509.5012.0022.692 16857917.0210.189.11113.90131.6364.8465.821.0747.0822.5840.72-9.6022.2021.26
UPE 180180.0075.005.5010.5012.0024.682 51263919.7214.9713.54150.41173.0273.4186.511.4458.2428.5651.30-9.4623.9226.59
UPE 200200.0080.006.0011.0013.0025.602 90169722.7720.9719.10190.96220.1381.13110.061.8773.1834.4362.20-11.3925.4132.56
UPE 220220.0085.006.5012.0013.0027.023 38775626.5929.2926.83243.89281.5289.00140.762.4691.2042.5176.88-12.4526.9740.34
UPE 240240.0090.007.0012.5015.0027.913 85281330.2439.1035.99299.95346.9596.66173.473.11111.4050.0890.85-14.3828.4148.19
UPE 270270.0095.007.5013.5015.0028.934 48589235.2056.5652.55389.28451.15108.25225.584.01138.6360.69110.22-16.1529.9058.94
UPE 300300.00100.009.5015.0015.0028.865 66296844.4583.6278.24521.61613.42117.55306.715.38186.2775.58136.72-19.4330.8275.90
UPE 330330.00105.0011.0016.0018.0029.006 7781 04353.21116.91110.09667.22792.01127.45396.006.81235.0289.66161.73-18.7331.7192.43
UPE 360360.00110.0012.0017.0018.0029.707 7921 12161.17156.71148.27823.75982.47137.95491.248.44284.08105.07189.25-18.8832.91109.62
UPE 400400.00115.0013.5018.0018.0029.779 1941 21872.17220.28209.831 049.161 262.81151.07631.4010.45350.97122.57220.84-18.2733.71130.76

Values are calculated with the Section Properties Calculator. They usually differ from published catalog values by about 0.5%, and by up to 1% in rare cases, mostly for small sections. See how the values are calculated.

About UPN and UPE channels

UPN and UPE are European hot-rolled channels to EN 10365. In both, the number in the designation is the depth in millimetres — UPN 200 is 200 mm deep. The difference is in the flanges: UPN flanges are tapered on the inside, while UPE flanges are parallel, slightly wider and thinner. UPE is the newer series. Parallel flanges make bolted and welded connections simpler, since no tapered washers are needed, and for a similar depth UPE is usually a little lighter.

A channel is not symmetric about its web, so its shear centre lies outside the section, on the outer side of the web, away from the flanges. A load applied through the web therefore tends to twist a single channel. This is why channels are used where the load acts close to the shear centre or the member is restrained against twisting: edge and trimmer beams fixed to a slab or wall, stair stringers, frames around openings and bracing. The flat back of the web is also convenient for fixing against a wall or another member.

Two channels placed back to back or toe to toe form a symmetric section without this twisting effect. Such built-up members are a common choice for columns, lattice chords and struts.

Notations

Symbols used in the UPN and UPE channel tables. Units are shown in the table headings.

Geometry and mass

Section
Profile designation in the EN 10365 catalogue.
h
Overall section depth.
b
Flange width.
tw
Web thickness.
tf
Flange thickness.
b1
Distance from the free flange edge to the point where flange thickness is measured.
i
Slope of the inner flange face for UPN (8% or 5%).
r1
Root radius at the web-to-flange junction.
r2
Toe radius at the free flange edge.
Cy
Centroid coordinate measured from the back of the web.
A
Cross-sectional area.
P
Perimeter of the section's outer contour.
Mass
Calculated mass per metre using a steel density of 7,850 kg/m³.

Bending properties

Iy, Iz
Second moments of area about the centroidal y–y and z–z axes.
Ip
Polar second moment of area about the centroid, equal to Iy + Iz.
Wy
Elastic section modulus about the y–y axis.
Wz,max, Wz,min
Elastic section moduli about the z–z axis at the back of the web (max) and at the flange tips (min).
iy, iz
Radii of gyration about the y–y and z–z axes, respectively: i = √(I/A).
Sy, Sz
First moments of one half of the section area about the centroidal y–y and z–z axes.

Plastic properties

Wpl,y, Wpl,z
Plastic section moduli about the plastic neutral axes for bending about y–y and z–z.
epl,z
Signed offset of the plastic neutral axis from z–z; negative values indicate a shift toward the web.

In the mm view, table headings scale fourth-power properties by 10⁶ and cubic properties by 10³. The displayed multiplier applies to the values in that column.